Kyoritsu 2040 AC Digital Clamp Meters
Kyoritsu 2040 AC Digital Clamp Meters KYORITSU Digital Clamp Meter Malaysia, Kuala Lumpur, KL, Singapore. Supplier, Suppliers, Supplies, Supply | Pacific Radio (M) Sdn Bhd
Download Files
Catalogue_KYORITSU_2040.pdf (407.83 KB)
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Thus, very useful for power distribution companies, power utilities and maintenance fields.
  • CAT4 600V
  • φ33
  • MAX600A
  • ACA
  • DCACV
  • Resistance
  • Continuitybuzzer
  • Frequency
  • DUTY
  • MAX/MIN
  • Relative
  • AutoPowerSave
 
AC A 0 - 600.0A
±1.5%rdg±5dgt (50/60Hz)
±3.5%rdg±8dgt (40 - 400Hz)
AC V 6/60/600V
Auto Ranging
±1.3%rdg±4dgt (50/60Hz)
±3.0%rdg±5dgt (40 - 400Hz)
DC V 600m/6/60/600V
Auto Ranging
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600 - 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9%
Conductor size Ø33mm
Applicable standards IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 243(L) × 77(W) × 36(D)mm
Weight 300g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8008 (Multi-Tran)

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf