Kyoritsu 8112 Clamp Sensors/Adaptors
Kyoritsu 8112 Clamp Sensors/Adaptors KYORITSU Clamp Sensors Malaysia, Kuala Lumpur, KL, Singapore. Supplier, Suppliers, Supplies, Supply | Pacific Radio (M) Sdn Bhd
Download Files
Instruction_Manual_Kyoritsu_8112.pdf (112.72 KB)
• AC CLAMP ADAPTOR 
• Model 8112 clamp adaptor is designed to be an AC current/voltage conversion probe capable of measuring AC current from 0.1mA to 120A in conjunction with digital multimeters.
Simple to operate, the unit has range switch position at 200mA,2A and 20A. It also features safety design throughout with no exposed metal parts.
  • ¦Õ8
  • MAX120A
  • ACA
 
Range Measuring Ranges Output Voltage Accuracy Frequency Response
200mA AC 0 - 500mA AC1V/A
(1000mA→1V)
 
±1.5%rdg±0.2mA 50Hz - 1kHz
AC 0 - 1000mA ±3%rdg±0.4mA 40Hz - 10kHz
2A AC 0 - 20A AC100mV/A
(20A→2V)
 
±1%rdg±1mA 40Hz - 1kHz
±1.5%rdg±2mA 1k - 10kHz
20A
 
AC 0 - 20A AC10mV/A
(120A→1.2V)
 
±1%rdg±0.01A 40Hz - 1kHz
AC 20 - 60A ±2.5%rdg 50Hz - 10kHz
AC 60 - 120A ±2.5%rdg 100Hz - 10kHz
Conductor Size Ø8mm max.
Frequency Characteristics 30Hz - 100kHz (-3dB)
Safety Standard IEC 61010-1 CAT II 100V Pollution Degree 2
Withstand Voltage 500V AC for 1 minute
Dimensions 153(L) × 18(W) × 23(D)mm
Weight 100g approx.
Accessories 9057 (Carrying Case)
Instruction Manual

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version