Fluke 975v AirMeter
Fluke 975v AirMeter FLUKE Air Tester Malaysia, Kuala Lumpur, KL, Singapore. Supplier, Suppliers, Supplies, Supply | Pacific Radio (M) Sdn Bhd
Download Files
FLUKE_975v.pdf (732.67 KB)
One Tool.
Get More Done.

The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimize HVAC ventilation settings for ASHRAE 62 recommendations, actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time. The Fluke 975 measures:

 

  • Temperature
  • Velocity
  • Humidity
  • CO2
  • CO

Use the Fluke 975 AirMeter test tool to:

 

  • Respond to comfort-related calls from occupants.
  • Verify the operation of building HVAC control systems.
  • Determine whether adequate ventilation exists.
  • Monitor air flow and velocity.
  • Test for dangerous carbon monoxide leaks.
  • Perform duct traversals.
  • Optimize HVAC systems to manage energy costs

Fluke 975

The Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter.

 

  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe*
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
  • Included FlukeView Forms® software
*Included with Fluke 975V, optional with Fluke 975

Measured specifications
Temperature
Range:  -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution:  0.1 °C (0.1 °F)
Accuracy:  ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range:  10 % to 90 % RH, non-condensing
Display Resolution:  1%
Accuracy:  ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range:  50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution:  1 fpm (0.005m/sec)
Accuracy:  ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
C0
Range:  0 to 500 ppm
Display Resolution:  1 ppm
Accuracy:  ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH
C02
Range:  0 to 5000 ppm
Display Resolution:  
1 ppm
Accuracy:  Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

 

Calculated specifications
Dew point temperature
Range:  -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution:  0.1 °C (0.1 °F)
Accuracy:  ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range:  -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution:  0.1 °C, (0.1 °F)
Accuracy:  ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range:  0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution:  0.001 M3/min, (1 cfm)
Accuracy:  N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range:  0 to 100%
Display Resolution:  0.1
% outside air (based on CO2)
Range:  0 to 100 %
Display Resolution:  0.1 % N/A

 

General specifications
Operating and storage temperature:
   -20 °C to 50 °C (-4 °F to 122 °F)
Humidity
   10 % to 90 % (non-condensing)
Altitude
   Up to 2000 m (6562 ft)
Shock and vibration
   MIL-PRF-28800F: Class 2
Multi-language interface
   English, French, Spanish, Portuguese and German
Battery
   Rechargeable Li-Ion (primary), three-AA (backup)
Data logging
   25,000 records (continuous), 99 records (discrete)

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version