Fluke 419D Laser Distance Meter
Fluke 419D Laser Distance Meter FLUKE Laser Distance Meter Malaysia, Kuala Lumpur, KL, Singapore. Supplier, Suppliers, Supplies, Supply | Pacific Radio (M) Sdn Bhd Fluke 419D Laser Distance Meter
  414D 419D 424D
Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3] ± 1.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3] ± 2.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft 80 m / 260 ft 100 m / 330 ft
Typical Range[1] 40 m / 130 ft 80 m  / 260 ft 80 m / 260 ft
Range at unfavorable condition[4] 35 m / 115 ft 60 m / 195 ft 60 m / 195 ft
Smallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm 
(10 / 50 / 100 m)
∅ laser point at distances 6 /30 / 60 mm 
(10 / 50 / 100 m)
6 /30 / 60 mm 
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No No ± 0.2°
Measuring tolerance to housing[5] No No ± 0.2°
Range No No 360°
General
Laser class 2
Laser type 635 nm, <1 mW
Protection class IP40 IP54
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 
measurements
Up to 5,000 
measurements
Size (H X W X L) 116mm Length
53mm Width 
33mm Depth
127mm Length 
56mm Width
33mm Depth
127mm Length 
56mm Width 
33mm Depth
Weight (with batteries) 113 g 153 g 158 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F) 

0 °C to +40 °C 
(32 °F to +104 °F)
-25 °C to +70°C 
(-13 °F to +158 °F) 

-10 °C to +50 °C 
(14 °F to +122 °F)
Calibration cycle Not applicable Not applicable Tilt and compass
Maximum altitude 3000 m 3000 m 3000 m
Maximum relative humidity 85% at 20 °F to 120°F 
(-7 °C to 50 °C)
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001 
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version